Shift Assignments

Speaker : Olga


Talk time : 10:00, Duration : 00:20

STAR Reconstruction Software

Under:
STAR   »

Comparing Data and MC with trigger

 I haven't resolved a sharp discrepancy between data and MC shape after trigger simulator is applied.

W-algo at mid-rapidity, bits & pieces

Development and vetting of mid rapidity W-reco algo  for 2009 run

updated: 11-24-08, changes 12-5-08

 

Master/Slave syncronization issues,tools,solutions etc...

This page is dedicated to variety of master/slave syncronization issues, tools and solutions used at STAR. It is made for internal usage, tutorial for offsite facilities would be created later.

Replication monitoring

Under:

Following tools are available for replication check:

Server list and various parameters

Here will be a server list (only those servers participating in various replication scenarios)

15 Broken BPRS channels ver=1.6, based on data from March of 2008

Under:

 The following BPRS pmts/tiles have been found broken or partially not functioning, based on reco MIP response from pp 2008 data.

 

14 ---- MIP gains ver=1.6 , 90% of 4800 tiles ----

Under:

 BPRS absolute gains using TPC MIPs & BTOW MIP cut, ver 1.6 , 2008 pp data

Technical Documentation of the Offline QA Shift Reports

Under:

 This page is meant to document technical details of files and databases used by the Offline QA Browser.

Cluster energy fraction in 3x3 patch: detector eta > 1.5

Energy fraction from NxN cluster in 3x3 patch: detector eta > 1.5

Figure 1a: 2x1/3x3 energy fraction [number of counts per given fraction]

Cluster energy fraction in 3x3 patch: detector eta < 1.5

Energy fraction from NxN cluster in 3x3 patch: detector eta < 1.5

Figure 1a: 2x1/3x3 energy fraction [number of counts per given fraction]

Finding a cut for corrupt scalers in Run 8 dAu

The problem

Cluster energy fraction in 0.7 radius: detector eta > 1.5

Energy fraction in NxN cluster within r=0.7 radius: detector eta < 1.5

Figure 1a: 2x1/0.7 energy fraction [number of counts per given fraction]

Cluster energy fraction in 0.7 radius: detector eta < 1.5

Energy fraction in NxN cluster within r=0.7 radius: detector eta < 1.5

Figure 1a: 2x1/0.7 energy fraction [number of counts per given fraction]

2008.11.21 Energy fraction from 2x1 vs. 2x2 vs. 3x3 or 0.7 radius: rapidity dependence

Ilya Selyuzhenkov November 21, 2008

Technical Documentation of the Offline QA Browser

Under:

This page is meant to document technical details of files and databases used by the Offline QA Browser. The databases reside on the duvall server.

EVP/RTS and impact on EMC

Speaker : Valeri Fine


Talk time : 16:00, Duration : 00:20

To test the new DAQ-READER (see: A DAQ Reader Cookbook ) based offline maker the new RTS DAQ-READER-based package can be checked

Minutes/Action Items


Talk time : 00:30, Duration : 00:20

Data Driven MC in Pion Analysis I

Invariant mass plots are shown with and without shower shape substitution being applied with Data Driven Maker (thanks Ilya).